Correlation Engine 2.0
Clear Search sequence regions


Sizes of these terms reflect their relevance to your search.

The sensors applied recently for determination of cholinesterase activity are mostly enzymatic amperometric sensors, in spite of their disadvantages: short life-time at ambient temperature, instability of the response, interferences, as well as passivation of the electrode surface. In the present paper a new approach for determination of cholinesterase activity was proposed, overcoming the main drawbacks of the analysis performed with amperometric enzymatic sensors. Instead of the immobilization of enzymes on a conducting electrode surface, whole cells of Arthrobacter globiformis, containing choline oxidase were fixed on a Clark type oxygen probe. Current proportional to bacteria respiration is registered as a sensor response. The application of whole cells of bacteria as a sensing element permits to achieve high stability of the response and long life-time of the sensor at ambient temperature, due to the conservation of the enzyme in its natural micro-environment inside the immobilized cells. The proposed sensor keeps its functionality more than 7 weeks stored in deionized water at ambient temperature. For the first 2 weeks the amplitude of the response decreases with only 10% and at the end of the studied 7 weeks period the response was 50% of the initial. The other advantages of the proposed sensor are: the dissolved oxygen is used as a mediator which concentration can be reliably and interferences free measured by the aim of a Clark type oxygen probe applied as a transducer; reproducible bacterial membranes can be elaborated by filtration of resuspended bacterial culture after preliminary determination of its activity; application of membranes containing lyophilized bacteria capable to be conserved infinitely long time and activated just before their application; negligible cost compared with the sensors based on immobilized enzymes. The steady-state response of the proposed bacterial sensor to choline obtained in 200 s is linear in the investigated concentration range up to 2 x 10(-4) moldm(-3), with detection limit of 8 x 10(-8) moldm(-3) and sensitivity of 4 x 10(-1) microAcm(3)mol(-1), at pH 6, temperature of 25 degrees C and stirring rate of 300 rpm. Choline is formed as a result of the catalytic hydrolysis (depending on the cholinesterase activity) of the substrate acetylcholine. Linear calibration graph for cholinesterase activity determination was obtained in the range up to 11 mUcm(-3), with a slope of 1.97 x 10(-2) microAcm(3)mU(-1), at pH 6, temperature of 25 degrees C and stirring rate of 300 rpm. The tests with reconstituted lyophilized serum with known activity used as a control sample confirm the accuracy of the proposed method. The relative error of the determination was only 2.82%.

Citation

Margarita Stoytcheva, Roumen Zlatev, Benjamin Valdez, Jean-Pierre Magnin, Zdravka Velkova. Electrochemical sensor based on Arthrobacter globiformis for cholinesterase activity determination. Biosensors & bioelectronics. 2006 Jul 15;22(1):1-9

Expand section icon Mesh Tags

Expand section icon Substances


PMID: 16376069

View Full Text