High performance thin layer chromatographic method is developed for simultaneous estimation of ibuprofen and pseudoephedrine hydrochloride in tablets. Silica gel 60F(254) plates were used as stationary phase and t.butanol: ethyl acetate: glacial acetic acid: water (7:4:2:2 v/v) as mobile phase. Wavelength selected for analysis was 254 nm. Percent estimation of ibuprofen and pseudoephedrine hydrochloride was found to be 99.56% and 98.77%, respectively. Percent recovery for both the drugs was found in the range of 98.27% to 100.91%, respectively.

Citation

S S Chitlange, D M Sakarkar, S B Wankhede, S G Wadodkar. High performance thin layer chromatographic method for simultaneous estimation of Ibuprofen and pseudoephedrine hydrochloride. Indian journal of pharmaceutical sciences. 2008 May-Jun;70(3):398-400


PMID: 20046759

View Full Text