Correlation Engine 2.0
Clear Search sequence regions


This was a retrospective analysis of the medium- to long-term results of 46 TC3 Sigma revision total knee replacements using long uncemented stems in press-fit mode. Clinical and radiological analysis took place pre-operatively, at two years post-operatively, and at a mean follow-up of 8.5 years (4 to 12). The mean pre-operative International Knee Society (IKS) clinical score was 42 points (0 to 74), improving to 83.7 (52 to 100) by the final follow-up. The mean IKS score for function improved from 34.3 points (0 to 80) to 64.2 (15 to 100) at the final follow-up. At the final follow-up 30 knees (65.2%) had an excellent result, seven (15.2%) a good result, one (2.2%) a medium and eight (17.4%) a poor result. There were two failures, one with anteroposterior instability and one with aseptic loosening. The TC3 revision knee system, when used with press-fit for long intramedullary stems and cemented femoral and tibial components, in both septic and aseptic revisions, results in a satisfactory clinical and radiological outcome, and has a good medium- to long-term survival rate.

Citation

P Manopoulos, E Havet, O Pearce, J F Lardanchet, P Mertl. Mid- to long-term results of revision total knee replacement using press-fit intramedullary stems with cemented femoral and tibial components. The Journal of bone and joint surgery. British volume. 2012 Jul;94(7):937-40

Expand section icon Mesh Tags

Expand section icon Substances


PMID: 22733949