Correlation Engine 2.0
Clear Search sequence regions


  • adult (1)
  • antibodies (2)
  • antigen class ii (3)
  • antigen hla (1)
  • b cell (5)
  • cases (3)
  • donor (1)
  • female (1)
  • globulin (1)
  • humans (1)
  • igg (2)
  • patients (1)
  • renal transplant (2)
  • Sizes of these terms reflect their relevance to your search.

    The objective of this study was to determine the mean fluorescence intensity (MFI) values of class II Luminex single antigen bead (L-SAB) assay and compare these MFI values with cell-based complement-dependent cytotoxicity crossmatch with anti-human globulin (CDC-AHG-XM) and IgG-B-cell flow cytometry crossmatch (FC-XM) results and explore the near-accurate MFI-cutoff values of positive cell-based crossmatch results. This retrospective study was an analysis in 97 renal transplant recipients, who were tested for the presence of DSA by CDC-AHG-XM and IgG-B-cell-FC-XM methods with their corresponding donor as well as for anti-human leukocyte antigen (HLA) antibody detection using a sensitive L-SAB assay. In the group having DSA MFI values <1000, none of the patients showed positivity for FC-XM and CDC-AHG-XM; in the group having MFI values between 1000 and 3000, 35.48% showed positivity for FC-XM but none by the CDC-AHG-XM method. However, in the group having MFI values >3000, 83.33% of cases were positive for FC-XM. Further, in those groups with MFI values between 3000 and 6000, 38.09% were positive for CDC-AHG-XM, while 86.66% showed positivity in the group with MFI >6000. Our results indicated that Luminex-DSA MFI value >1995 (P < .0001) significantly correlated with IgG-B-cell-FC-XM positivity while Luminex-DSA MFI value of >4247 (P < .0006) was significantly correlated with positive CDC-AHG-XM. MFI cutoff of 1995 exhibited a diagnostic sensitivity of 97.56% and specificity of 89.29% for predicting positive IgG B-cell FC-XM and MFI cutoff of 4247 exhibited a diagnostic sensitivity of 90.48% and specificity of 97.37% for predicting positive CDC-AHG-XM. However, a cutoff MFI of >5000 and >7000 for SAB assay had a sensitivity and specificity of 100% in detecting a positive IgG B-cell FC-XM and CDC-AHG-XM, respectively.

    Citation

    Amit Pande, Prashant Pandey, Amit Kumar Devra, Vijay Kumar Sinha, Anil Prasad Bhatt. Significance of Luminex-based single antigen class II bead assay and its mean fluorescence intensity in renal transplant cases; a retrospective observation in 97 cases. Journal of immunoassay & immunochemistry. 2020 May 03;41(3):322-336

    Expand section icon Mesh Tags

    Expand section icon Substances


    PMID: 32122239

    View Full Text