A 50-year-old woman with cornea plana had reduced visual acuity due to development of lenticular changes. Flat keratometry with high astigmatism, shallow anterior chamber depth, and short axial length made it challenging both for intraocular lens (IOL) power calculation and cataract surgery. Surgery was planned for the right eye because the left eye was densely amblyopic. IOL power required was beyond the commercially available lenses; hence, a customized toric IOL was obtained. Phacoemulsification was successfully performed along with in-the-bag implantation of the toric IOL, which resulted in improved visual acuity with satisfactory refractive outcome. Cataract surgery with a customized IOL improved visual acuity in an eye with cornea plana.

Citation

Rajesh Fogla, Thazethaeveetil R Indumathy. Customized toric intraocular lens implantation in cornea plana. Journal of cataract and refractive surgery. 2020 Dec;46(12):e11-e14