Correlation Engine 2.0
Clear Search sequence regions


filter terms:
Sizes of these terms reflect their relevance to your search.

Objective: To establish a headspace solid phase microextraction-gas chromatography method for determination of n-Butyl alcohol in urine. Methods: In October 2019, the n-butyl alcohol in urine was extracted with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) solid-phase microextraction head. The conditions of salt amount, extraction temperature, extraction time and desorption time were optimized. The separation was performed on HP-5 (30 m×0.32 mm×0.25 μm) capillary column and detected with flame ionization detector. The quantification was based on the external standard curve. Results: The linear relationship of n-butyl alcohol in urine was good in the range of 0.04-3.00 mg/L, the correlation coefficient was 0.999, the detection limit of the method was 0.04 mg/L, the recovery was 77.4%-102.8%, the intra-run precision was 3.67%-8.11%, and the inter-assay precision was 4.94%-6.90%. Conclusion: The method has simple operation, high concentration efficiency and high sensitivity, and it is suitable for the determination of n-butyl alcohol in urine of occupational exposure to n-butyl alcohol.

Citation

H C Chen, S J Peng, H M Gao, W T Su, Y Mei, G L Yi. Determination of n-butyl alcohol in urine by headspace solid-phase microextraction coupled with gas chromatography]. Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases. 2020 Dec 20;38(12):932-935