Correlation Engine 2.0
Clear Search sequence regions


Sizes of these terms reflect their relevance to your search.

Renal blood flow (RBF) can be measured with dynamic contrast enhanced-MRI (DCE-MRI) and arterial spin labeling (ASL). Unfortunately, individual estimates from both methods vary and reference-standard methods are not available. A potential solution is to include a third, arbitrating MRI method in the comparison. To compare RBF estimates between ASL, DCE, and phase contrast (PC)-MRI. Prospective. Twenty-five patients with type-2 diabetes (36% female) and five healthy volunteers (HV, 80% female). A 3 T; gradient-echo 2D-DCE, pseudo-continuous ASL (pCASL) and cine 2D-PC. ASL, DCE, and PC were acquired once in all patients. ASL and PC were acquired four times in each HV. RBF was estimated and split-RBF was derived as (right kidney RBF)/total RBF. Repeatability error (RE) was calculated for each HV, RE = 1.96 × SD, where SD is the standard deviation of repeat scans. Paired t-tests and one-way analysis of variance (ANOVA) were used for statistical analysis. The 95% confidence interval (CI) for difference between ASL/PC and DCE/PC was assessed using two-sample F-test for variances. Statistical significance level was P < 0.05. Influential outliers were assessed with Cook's distance (Di  > 1) and results with outliers removed were presented. In patients, the mean RBF (mL/min/1.73m2 ) was 618 ± 62 (PC), 526 ± 91 (ASL), and 569 ± 110 (DCE). Differences between measurements were not significant (P = 0.28). Intrasubject agreement was poor for RBF with limits-of-agreement (mL/min/1.73m2 ) [-687, 772] DCE-ASL, [-482, 580] PC-DCE, and [-277, 460] PC-ASL. The difference PC-ASL was significantly smaller than PC-DCE, but this was driven by a single-DCE outlier (P = 0.31, after removing outlier). The difference in split-RBF was comparatively small. In HVs, mean RE (±95% CI; mL/min/1.73 m2 ) was significantly smaller for PC (79 ± 41) than for ASL (241 ± 85). ASL, DCE, and PC RBF show poor agreement in individual subjects but agree well on average. Triangulation with PC suggests that the accuracy of ASL and DCE is comparable. 2 TECHNICAL EFFICACY: Stage 2. © 2021 International Society for Magnetic Resonance in Medicine.

Citation

Bashair A Alhummiany, David Shelley, Margaret Saysell, Maria-Alexandra Olaru, Bernd Kühn, David L Buckley, Julie Bailey, Kelly Wroe, Cherry Coupland, Michael W Mansfield, Steven P Sourbron, Kanishka Sharma. Bias and Precision in Magnetic Resonance Imaging-Based Estimates of Renal Blood Flow: Assessment by Triangulation. Journal of magnetic resonance imaging : JMRI. 2022 Apr;55(4):1241-1250

Expand section icon Mesh Tags

Expand section icon Substances


PMID: 34397124

View Full Text