Burcu Barutcuoglu, Nevin Oruc, Güneş Ak, Serdar Kucukokudan, Ahmet Aydın, Deniz Nart, Mustafa Harman
Annals of clinical biochemistry 2022 MarPancreatic cyst fluid analysis plays an important role in distinguishing between mucinous and non-mucinous cyst lesions. We aimed to compare the diagnostic performances of cyst fluid carcinoembryonic antigen (CEA), CA 19-9, and glucose in differentiating mucinous from non-mucinous neoplastic pancreatic cystic lesions (PCLs) and determine the best cut-off levels. Patients' data were evaluated retrospectively. 102 patients' PCLs were grouped as non-neoplastic (n = 25), non-mucinous neoplastic (n = 20), mucinous neoplastic (n = 47) and pancreatic adenocarcinomas with cystic degeneration (n = 10); and CEA, CA 19-9, and glucose levels were compared. Receiver-operating characteristic analysis was performed, and the ideal cut-off values were determined. Cyst fluid CEA and CA 19-9, levels were significantly higher (P < 0.001, P < 0.001, respectively) and glucose levels were significantly lower (P = 0.001) in mucinous than in non-mucinous neoplastic PCLs. Area under curve with 95% confidence interval of CEA, glucose and CEA and glucose test combination was 0.939 (95% CI = 0.885-0.993, P = 0.001), 0.809 (95% CI = 0.695-0.924, P < 0.001) and 0.937 (95% CI = 0.879-0.995), respectively. CEA cut-offs to rule-in and rule-out mucinous neoplastic were 135.1 ng/mL (sensitivity = 62%, specificity = 94.7%) and 6.12 ng/mL (sensitivity = 94.1%, specificity = 80.4%), respectively. Glucose cut-off of 2.8 mmol/L was chosen both to rule-in and rule-out mucinous neoplastic PCLs (sensitivity = 78%, specificity = 80%). Co-analysis of CEA and glucose to distinguish mucinous from non-mucinous neoplastic PCLs had sensitivity = 87.8%, specificity = 93.3%, and diagnostic accuracy = 89.3%. We concluded that co-analysis of cyst fluid CEA (cut-off = 135.1 ng/mL) and glucose (cut-off = 2.8 mmol/L) at novel cut-offs had the best testing performance to rule-in mucinous neoplastic PCLs. To rule-out mucinous PCLs co-analysis of CEA (cut-off = 6.12 ng/mL) and glucose (cut-off = 2.8 mmol/L) added value to prediction.
Burcu Barutcuoglu, Nevin Oruc, Güneş Ak, Serdar Kucukokudan, Ahmet Aydın, Deniz Nart, Mustafa Harman. Co-analysis of pancreatic cyst fluid carcinoembryonic antigen and glucose with novel cut-off levels better distinguishes between mucinous and non-mucinous neoplastic pancreatic cystic lesions. Annals of clinical biochemistry. 2022 Mar;59(2):125-133
PMID: 34719238
View Full Text