Correlation Engine 2.0
Clear Search sequence regions


  • evolut (12)
  • heart (3)
  • humans (1)
  • prosthesis (1)
  • prosthesis design (1)
  • THVs (3)
  • Sizes of these terms reflect their relevance to your search.

    This study sought to determine the degree of Evolut (Medtronic) leaflet pinning, diameter expansion, leaflet overhang, and performance at different implant depths of the balloon-expandable Sapien 3 (S3, Edwards Lifesciences LLC) transcatheter heart valve (THV) within the Evolut THV. Preservation of coronary access and flow is a major factor when considering the treatment of failed Evolut THVs. An in vitro study was performed with 20-, 23-, 26-, and 29-mm S3 THVs deployed within 23-, 26-, 29-, and 34-mm Evolut R THVs, respectively. The S3 outflow was positioned at various depths at node 4, 5, and 6 of the Evolut R. Neoskirt height, leaflet overhang, performance, and Evolut R valve housing diameter expansion were assessed under physiological conditions as per ISO 5840-3 standard. The neoskirt height for the Evolut R was shorter when the S3 outflow was positioned at node 4 compared with node 6 (node 4 height for 23 mm = 16.3 mm, 26 mm = 17.1 mm, 29 mm = 18.3 mm, and 34 mm = 19.9 mm vs node 6 height for 23 mm = 23.9 mm, 26 mm = 23.4 mm, 29 mm = 24.7 mm, and 34 mm = 27 mm Evolut R). All configurations exhibited acceptable hydrodynamic performance irrespective of the degree of leaflet overhang, except the 29-mm S3 implanted in 34-mm Evolut R at node 4 (regurgitant fraction >20%). The valve housing radius of the index Evolut R increased when the S3 was implanted, with the increase ranging from 0 to 2.5 mm. Placement of the S3 at a lower implant position within an index Evolut R reduces the neoskirt height with no significant compromise to S3 valve function despite a higher degree of leaflet overhang. Low S3 implantation may facilitate future coronary access after redo transcatheter aortic valve replacement. Copyright © 2022 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

    Citation

    Mariama Akodad, Stephanie Sellers, Uri Landes, David Meier, Gilbert H L Tang, Hemal Gada, Toby Rogers, Michael Caskey, Bruce Rutkin, Rishi Puri, Joshua Rovin, Jonathon Leipsic, Lars Sondergaard, Kendra J Grubb, Patrick Gleason, Kshitija Garde, Hatem Tadros, Sebastian Teodoru, David A Wood, John G Webb, Janarthanan Sathananthan. Balloon-Expandable Valve for Treatment of Evolut Valve Failure: Implications on Neoskirt Height and Leaflet Overhang. JACC. Cardiovascular interventions. 2022 Feb 28;15(4):368-377

    Expand section icon Mesh Tags


    PMID: 35210043

    View Full Text