    A novel non-destructive testing scanning system based on a large-size line array fast neutron detector and compact D-T neutron source has been constructed. The scanning range is up to 1000 mm, and the resolution is better than 1 mm. The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. With a new rotating tritium target, the lifetime of the compact D-T neutron source could achieve ten hours. The experimental results indicate that the scanning method based on line array fast neutron detector and D-T neutron source is feasible and enables the detection of slits on the order of 0.5 mm in width. Fast neutron tomography has been realized by this detection system too.

    Citation

    Sheng Wang, Chao Cao, Wei Yin, Yang Wu, Heyong Huo, Yong Sun, Bin Liu, Xin Yang, Rundong Li, Shilei Zhu, Chunlei Wu, Hang Li, Bin Tang. A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source. Materials (Basel, Switzerland). 2022 Jul 15;15(14)


    PMID: 35888411