Correlation Engine 2.0
Clear Search sequence regions


Sizes of these terms reflect their relevance to your search.

Objective: To design a visual fatigue questionnaire that can be used for population surveys. Methods: This was a cross-sectional study that involved three stages of subjects' recruitment. In the first stage, by convenience sampling, 150 individuals who complained of visual fatigue were selected at public places in Wenzhou City in May 2016. The 19-Item Asthenopia Survey Questionnaire (ASQ-19) was used to conduct the survey, and the questionnaire was adjusted. In the second stage, 200 outpatient participants were recruited from Wenzhou Medical University Affiliated Eye and Optometry Hospital from June 2016 to May 2017 and were divided into a visual fatigue group and a control group based on clinical diagnosis. The adjusted visual fatigue questionnaire was used for validation. In the third stage, 64 outpatient participants who met the inclusion criteria were continuously recruited from the Wenzhou Medical University Affiliated Eye and Optometry Hospital in July 2022. They were tested using the adjusted visual fatigue questionnaire and retested one week later. During the questionnaire adjustment stage, factor analysis and feedback were used to adjust the scoring method and items of the ASQ-19 questionnaire. The adjusted questionnaire was then analyzed for reliability, validity, accuracy, and subject acceptance during the validation and retest stages. Results: A total of 403 participants were included, and 456 questionnaires were distributed. Eventually, 432 valid questionnaires were collected from 379 participants, resulting in a valid response rate of 94.7%. During the questionnaire adjustment phase, there were 140 valid questionnaires from 140 participants consisting of 56 males and 84 females with an average age of (35.2±12.4) years. In the questionnaire validation phase, there were 186 valid questionnaires from 186 participants. Sixty-two participants had visual fatigue and 124 were controls. During the questionnaire retesting phase, 53 participants yielded 106 valid questionnaires. The group consisted of 20 males and 33 females with an average age of (22.8±4.9) years. After factor analysis, the symptom severity graded as none, mild, moderate, severe, and very severe was scored as 0, 1, 2, 3, and 4 points, respectively. The total score was 44, and the final questionnaire consisted of 11 items (numbered 1, 2, 3, 5, 6, 8, 10, 15, 17, 18, and 19). The 11-Item Asthenopia Survey Questionnaire (ASQ-11) had a Cronbach's α coefficient of 0.89, a split-half reliability of 0.82, and a test-retest Pearson correlation coefficient of 0.90 (P<0.001). The structural validity was 51.26%, and the discriminative validity was a t-value of 9.19 (P<0.001). On average, it took (2.82±0.43) minutes for participants to complete the questionnaire. The receiver operating characteristic curve had a cutoff value of 8.5, with a sensitivity of 74.19% and a specificity of 80.65%. Conclusion: The ASQ-11, with fewer items and a shorter completion time, is easy for participants to use and is suitable for screening or self-assessment of visual fatigue in the general population. Additionally, it is convenient for clinical and epidemiological studies related to visual fatigue.

Citation

R Z Deng, L Tian, X Q Sun, J F Zhang, N Lin, Y Y Lin, F Lyu. Development of an asthenopia survey questionnaire for general surveys]. [Zhonghua yan ke za zhi] Chinese journal of ophthalmology. 2023 Jun 11;59(6):452-459

Expand section icon Mesh Tags


PMID: 37264575

View Full Text